The efficiency of luminescence emission must be regarded on an energy and a quantum basis.
When every exciting photon yields an emitted photon of the same energy (as is the case for resonance excitation—i.e., excitation of fluorescence by a monochromatic light of exactly the same wavelengths as the resulting fluorescence—and radiation of isolated atoms in dilute gases), the luminescence efficiency is cent percent with respect to input energy as well as to the number of quanta.
When the number of secondary photons is equal to that of the primary but their energy is less because some energy is dissipated as heat, the quantum efficiency is cent percent.
The light intensity of luminescent processes depends chiefly on the excitation intensity, the density, and the lifetime of the radiative atoms, molecules, or centres.
For practical purposes this luminous intensity per unit area is called photometric brightness or luminance of a material and is measured in lambert or millilambert units.
The continuous expansion of the sensor market, with particular emphasis on temperature sensors, is a response to the increasing demand for the analysis of temperature changes in various scientific fields and industry.
The Global Luminescence efficiency measurement system market accounted for $XX Billion in 2022 and is anticipated to reach $XX Billion by 2030, registering a CAGR of XX% from 2023 to 2030.
Oriel’s QEPVSI-b is a preconfigured, yet flexible solution for measuring Quantum Efficiency (QE), also known as Incident Photo to Charge Carrier Efficiency (IPCE).
Industry leading components ensure accuracy and repeatability. Oriel’s TracQ Basic software provides instrument setup, control, data collection, and export.
The QEPVSI-b is assembled and tested by Oriel Instruments, an industry leader in light sources and spectroscopy.
Oriel provides the expertise to ensure accuracy of the solution’s performance. Modulated light from a Xenon source is sent through order sorting filters and into an Oriel Cornerstone 260 monochromator to generate a monochromatic light output.
The output beam path is then focused to a well-defined area. The monochromator scans over a user-selectable wavelength range with the output focused onto the calibrated silicon reference detector providing the radiometric measurement.
They provide the most reliable temperature readout, enable simple measurement, and entail low equipment cost, the most popular and most often described methods are ratiometric approaches and a technique that uses the disappearance of luminescence.