
- Get in Touch with Us
Last Updated: Apr 25, 2025 | Study Period: 2024-2030
The characterization of anodized indium tin oxide (anodized-ITO) as a Sodium Electrodes and the comparison of three different structuresâa sodium-selective membrane/anodized-ITO as sensor 1, an anodized-ITO membrane as the contrast sensor 2, and an ITO as the reference electrodeâare the main goals of this work.
Anodic oxidation, a low-cost and straightforward manufacturing procedure that makes it simple to control the variance in film resistance, was used to create anodized-ITO at ambient temperature. From pH 2 to pH 12, the anodized-ITO-based EGFET structure exhibits good linear pH sensitivity, measuring 54.44 mV/pH.
The suggested sodium electrodes, which were created using PVC-COOH, a DOS embedding colloid, the complex Na-TFBD, and the ionophore B12C4, exhibit good sensitivity at 52.48 mV/decade for 104 M to 1 M and 29.96 mV/decade for higher concentrations
The Global Sodium Electrodes market accounted for $XX Billion in 2023 and is anticipated to reach $XX Billion by 2030, registering a CAGR of XX% from 2024 to 2030.
Silver/silver chloride (Ag/AgCl) reference electrode and Sodium Electrodes are both components of the FC300B electrode. Both are included in a single glass body design with an electrolyte fill solution made of ammonium chloride and silver chloride.
Before performing a calibration, the sodium-sensitive membrane needs to be condition. The glass is etched and then rehydrated during the two-step process of conditioning the electrode.
Etching is the initial stage. This procedure exposes a new, sodium-containing surface by removing a tiny layer of delicate glass from the sodium membrane. The glass membrane is rehydrated in the second stage, which involves placing the probe in a storage solution.
Utilize Thermo Scientific's Orion Sodium Electrodes to quickly, precisely, and affordably measure sodium in aqueous solutions. Compared to traditional sodium electrodes, a Thermo Scientific Orion ROSS electrode has a unique redox internal system that offers faster response times, more stability, and greater precision.
Includes:Cables for sodium BNC electrodes are 1 m long.50 mL of ROSS sodium electrode filling fluid,Adjustor for sodium ionic strength (ISA): 475 mL,Standard for sodium addition with known concentration: 475mL 1000 ppm sodium standard with ISA: 475mL,475 mL of the sodium reconditioning solution.475 mL of sodium electrode storage solution
.
Sl no | Topic |
1 | Market Segmentation |
2 | Scope of the report |
3 | Abbreviations |
4 | Research Methodology |
5 | Executive Summary |
6 | Introdauction |
7 | Insights from Industry stakeholders |
8 | Cost breakdown of Product by sub-components and average profit margin |
9 | Disruptive innovation in theIndustry |
10 | Technology trends in the Industry |
11 | Consumer trends in the industry |
12 | Recent Production Milestones |
13 | Component Manufacturing in US, EU and China |
14 | COVID-19 impact on overall market |
15 | COVID-19 impact on Production of components |
16 | COVID-19 impact on Point of sale |
17 | Market Segmentation, Dynamics and Forecast by Geography, 2024-2030 |
18 | Market Segmentation, Dynamics and Forecast by Product Type, 2024-2030 |
19 | Market Segmentation, Dynamics and Forecast by Application, 2024-2030 |
20 | Market Segmentation, Dynamics and Forecast by End use, 2024-2030 |
21 | Product installation rate by OEM, 2023 |
22 | Incline/Decline in Average B-2-B selling price in past 5 years |
23 | Competition from substitute products |
24 | Gross margin and average profitability of suppliers |
25 | New product development in past 12 months |
26 | M&A in past 12 months |
27 | Growth strategy of leading players |
28 | Market share of vendors, 2023 |
29 | Company Profiles |
30 | Unmet needs and opportunity for new suppliers |
31 | Conclusion |
32 | Appendix |